{"id":3736,"date":"2026-11-18T19:04:35","date_gmt":"2026-11-18T11:04:35","guid":{"rendered":"http:\/\/www.kd-trip.com\/blog\/?p=3736"},"modified":"2026-11-18T19:04:35","modified_gmt":"2026-11-18T11:04:35","slug":"how-to-reset-a-poclain-hydraulic-motor-4a78-3bf11e","status":"publish","type":"post","link":"http:\/\/www.kd-trip.com\/blog\/2026\/11\/18\/how-to-reset-a-poclain-hydraulic-motor-4a78-3bf11e\/","title":{"rendered":"How to reset a Poclain hydraulic motor?"},"content":{"rendered":"<p>If you work in industries like construction, agriculture, mining, or material handling, chances are you rely on Poclain hydraulic motors for their unmatched durability, compact design, and consistent performance. As a Poclain hydraulic motor supplier, I\u2019ve spent years walking customers through maintenance and troubleshooting, and one of the most common questions I get is: \u201cHow do I reset a Poclain hydraulic motor after it trips a fault, overheats, or starts acting unpredictably?\u201d Resetting these motors isn\u2019t just about pressing a button\u2014it\u2019s a process that, when done correctly, gets your equipment back online fast without risking damage to the motor or your machinery. <a href=\"https:\/\/www.jinjiahyd.com\/hydraulic-motor\/poclain-hydraulic-motor\/\">Poclain Hydraulic Motor<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.jinjiahyd.com\/uploads\/26311\/small\/jinjia-radial-piston-motor-worry-free-export38f06.jpg\"><\/p>\n<p>First, let\u2019s make something clear: Poclain hydraulic motors are designed with built-in safety features to prevent catastrophic failure. Those safety mechanisms\u2014like pressure relief valves, over-temperature sensors, and load monitors\u2014will trip to shut the motor down if they detect a problem that could cause harm. That trip isn\u2019t a \u201cglitch\u201d; it\u2019s a warning. Resetting the motor before you identify and fix the root cause of the trip will only lead to more serious issues, from reduced torque to complete motor failure. That\u2019s why I always tell customers: start with troubleshooting, then reset. That\u2019s the approach I\u2019m going to break down here, step by step, based on years of working with these motors and knowing their inner workings.<\/p>\n<p>Let\u2019s start with pre-reset checks. These are non-negotiable. Skipping them is the number one reason customers call me back a week later with a motor that\u2019s already tripped again. First, check the fluid level and quality. Hydraulic fluid is the lifeblood of the motor. If the level is too low, the motor will starve for fluid, cause overheating, and trigger a fault. Pull the dipstick on your hydraulic reservoir (make sure the equipment is level, and the engine is turned off and cooled down\u2014hot fluid will give a false reading) and check the fluid. If it\u2019s low, top it up with the exact type specified in your equipment manual. Poclain motors use anti-wear hydraulic fluid, usually ISO 46 or ISO 68, depending on the model. If the fluid looks cloudy, has a burnt smell, or has metal shavings in it, that\u2019s a sign of internal wear. Don\u2019t just top it up\u2014drain and replace the entire fluid and filter before proceeding. Metal shavings are a red flag; they mean parts inside the motor are wearing down, and resetting without addressing that will destroy the motor.<\/p>\n<p>Next, inspect the pressure lines. Poclain motors operate at high pressures, usually between 200 and 400 bar, depending on the model. A clogged line, kinked hose, or faulty connection can cause pressure spikes that trip the motor\u2019s safety valve. Turn off the equipment, release any residual pressure from the lines (this is important\u2014stand clear when loosening fittings, as trapped pressure can spray hot fluid), and check all hoses and connections. Look for cracks, bulges, or loose fittings. If a hose is kinked or cracked, replace it immediately. Loose fittings can be tightened with a wrench, but don\u2019t over-tighten\u2014you can damage the threads or the seal. Also, make sure the relief valve setting on your system matches the Poclain motor\u2019s specifications. If someone adjusted the relief valve higher than the motor\u2019s rating, that\u2019s a surefire way to trigger trips.<\/p>\n<p>Then, check for overheating. Poclain motors have temperature sensors that trip if the fluid gets too hot, usually around 85\u00b0C (185\u00b0F) for most standard models. If your equipment has been running heavy loads in hot weather, or if the cooling system for the hydraulic circuit is blocked, that could be the cause. Let the motor cool completely\u2014this can take 30 minutes to an hour, depending on how hot it was. Don\u2019t try to reset a hot motor; the heat will cause internal seals to expand, and resetting under heat can lead to seal failure. Also, check the cooling fins on the motor if it\u2019s an exposed model\u2014if they\u2019re clogged with dirt or debris, clean them with a soft brush or compressed air to restore airflow.<\/p>\n<p>Now, once you\u2019ve completed those pre-reset checks and confirmed there\u2019s no immediate issue, you can move on to the actual reset process. The method here depends on whether your Poclain motor is connected to a manual control system or a digital control system, which is common on newer equipment. Let\u2019s cover both.<\/p>\n<p>For motors with manual controls: Most entry-level or older Poclain motor installations have a manual reset button on the motor\u2019s control module or on the equipment\u2019s dashboard. This button is usually red and clearly labeled \u201cRESET\u201d or \u201cFAULT RESET.\u201d Here\u2019s how to use it: first, make sure all controls are in neutral. Turn off the engine, wait 10 seconds to let the system power down completely, then turn the key back to the \u201cON\u201d position (don\u2019t start the engine yet). Press and hold the reset button for 3 to 5 seconds, then release it. Some models will have a small indicator light that blinks during a fault and turns solid once reset. If the light stays on, the fault is still present\u2014go back and recheck your pre-reset steps. If the light turns off, you can start the engine and test the motor at low speed first to make sure it\u2019s working correctly.<\/p>\n<p>For motors with digital control systems: Newer Poclain motors (like the MS Series or MHP Series) often come with electronic control units (ECUs) that display fault codes. Resetting these requires using the equipment\u2019s diagnostic interface, which could be a handheld scan tool or a tablet connected to the vehicle\u2019s OBD port. First, pull up the fault code to confirm why the motor tripped. Poclain\u2019s fault codes are standardized\u2014for example, code E01 might be over-pressure, E03 could be over-temperature, and E05 might be low fluid pressure. Once you\u2019ve addressed the root cause, navigate to the \u201cFault Reset\u201d menu in the diagnostic interface and select \u201cReset Motor Fault.\u201d Some systems will ask you to confirm the action; make sure you do that, as resetting without clearing the fault will leave a permanent log entry that can cause issues with future diagnostics. After resetting, clear the fault code from the system\u2019s memory, then test the motor at low load to ensure it\u2019s operating smoothly.<\/p>\n<p>Wait\u2014there\u2019s one more thing: some Poclain motors have a built-in manual override for pressure that can be mistaken for a reset. Don\u2019t adjust the pressure relief valve unless you\u2019re familiar with your model\u2019s specifications. Adjusting it incorrectly will void your warranty and could cause the motor to fail. If you\u2019re unsure about your model\u2019s settings, reach out to a Poclain Hydraulic Motor supplier like myself before making any changes.<\/p>\n<p>Now, what if the motor still trips after resetting? That\u2019s a sign there\u2019s a deeper issue. Common causes here include worn internal components (like the pistons, bearings, or seals), a faulty sensor, or a problem with the hydraulic pump itself. For example, if the pump isn\u2019t delivering consistent pressure, it will cause the motor to work harder than it should, leading to trips. If you\u2019ve gone through all the pre-reset steps and the motor still won\u2019t stay reset, it\u2019s time to inspect the motor internally. To do this, you\u2019ll need to remove the motor from the equipment, disassemble it carefully, and check for signs of wear. If you\u2019re not comfortable doing this, I always recommend bringing it to a certified technician\u2014trying to disassemble the motor without experience can damage parts beyond repair.<\/p>\n<p>As a Poclain hydraulic motor supplier, I\u2019ve seen customers waste hundreds of dollars on unnecessary repairs because they reset the motor without troubleshooting first. Taking the time to check fluid, lines, and temperature before resetting will save you time and money in the long run. Also, regular maintenance can prevent most trip issues. Flushing the hydraulic fluid every 1,000 hours, replacing filters every 500 hours, and inspecting hoses for wear will keep your Poclain motor running smoothly for years.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.jinjiahyd.com\/uploads\/26311\/small\/ms25-radial-piston-hydraulic-motor-low-speede138c.jpg\"><\/p>\n<p>If you\u2019re dealing with a persistent fault, need a replacement part for your Poclain motor, or are ready to upgrade your hydraulic system, don\u2019t hesitate to reach out. I work directly with customers across industries to provide genuine Poclain parts, troubleshooting support, and guidance on maintenance to keep your equipment operational. Whether you\u2019re a small farm owner managing a tractor or a construction company with a fleet of excavators, I\u2019m here to help you get the most out of your Poclain hydraulic motors. Just connect with me to discuss your needs and find the right solution for your equipment.<\/p>\n<p><a href=\"https:\/\/www.jinjiahyd.com\/hydraulic-motor\/poclain-hydraulic-motor\/\">Poclain Hydraulic Motor<\/a> References:<\/p>\n<ol>\n<li>Poclain Hydraulics Service Manual for MS Series Hydraulic Motors, 2022<\/li>\n<li>Hydraulic Maintenance Handbook, National Fluid Power Association, 2021<\/li>\n<li>Troubleshooting Guide for Poclain Hydraulic Motor Faults, Poclain Hydraulics Technical Support, 2023<\/li>\n<li>ISO Standards for Hydraulic Fluid Compatibility, International Organization for Standardization, 2020<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.jinjiahyd.com\/\">Jining Jinjia Hydraulic Co., Ltd.<\/a><br \/>Jining Jinjia Hydraulic Co., Ltd. is one of the most professional poclain hydraulic motor manufacturers and suppliers in China, specialized in providing high quality orbit hydraulic motors. We warmly welcome you to buy customized poclain hydraulic motor at competitive price from our factory.<br \/>Address: Jining New Material Industrial Park, Shandong, China.<br \/>E-mail: Sales@jinjiahyd.com<br \/>WebSite: <a href=\"https:\/\/www.jinjiahyd.com\/\">https:\/\/www.jinjiahyd.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you work in industries like construction, agriculture, mining, or material handling, chances are you rely &hellip; <a title=\"How to reset a Poclain hydraulic motor?\" class=\"hm-read-more\" href=\"http:\/\/www.kd-trip.com\/blog\/2026\/11\/18\/how-to-reset-a-poclain-hydraulic-motor-4a78-3bf11e\/\"><span class=\"screen-reader-text\">How to reset a Poclain hydraulic motor?<\/span>Read more<\/a><\/p>\n","protected":false},"author":949,"featured_media":3736,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[3699],"class_list":["post-3736","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-poclain-hydraulic-motor-4e3a-3c9abe"],"_links":{"self":[{"href":"http:\/\/www.kd-trip.com\/blog\/wp-json\/wp\/v2\/posts\/3736","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.kd-trip.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.kd-trip.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.kd-trip.com\/blog\/wp-json\/wp\/v2\/users\/949"}],"replies":[{"embeddable":true,"href":"http:\/\/www.kd-trip.com\/blog\/wp-json\/wp\/v2\/comments?post=3736"}],"version-history":[{"count":0,"href":"http:\/\/www.kd-trip.com\/blog\/wp-json\/wp\/v2\/posts\/3736\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.kd-trip.com\/blog\/wp-json\/wp\/v2\/posts\/3736"}],"wp:attachment":[{"href":"http:\/\/www.kd-trip.com\/blog\/wp-json\/wp\/v2\/media?parent=3736"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.kd-trip.com\/blog\/wp-json\/wp\/v2\/categories?post=3736"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.kd-trip.com\/blog\/wp-json\/wp\/v2\/tags?post=3736"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}